nRF51 SDK
 All Data Structures Functions Variables Typedefs Enumerations Enumerator Groups Pages
Running Speed and Cadence Application

Modules

 main.c
 Running Speed and Cadence Service Sample Application main file.
 

Detailed Description

The Running Speed and Cadence Application is a firmware example that implements the Running Speed and Cadence profile using the hardware delivered in the nRF51822 Development Kit.

The source code and project file can be found in the <InstallFolder>\Nordic\nrf51822\Board\nrf6310\ble\ble_app_rscs folder.

The application includes the two services in the Running Speed and Cadence profile:

In addition, use of the Battery Service is also demonstrated.

When the application starts, it starts a timer to simulate Running Speed and Cadence Measurements.

Also, a timer for generating battery measurements is started.

The sensor measurements are simulated the following way:

When notification of Running Speed and Cadence Measurement characteristic is enabled, the Running Speed and Cadence Measurement, containing the current value for all the components of the Running Speed and Cadence Measurement characteristic, is notified each time the Running Speed and Cadence measurement timer expires. When notification of Battery Level characteristic is enabled, the Battery Level is notified each time the Battery Level measurement timer expires.

Note
This application is not power optimised!
The application will stop advertising after 3 minutes and go to system-off mode. Push the button 0 restart advertising.

Setup

Instructions on how to set up the nRFgo Motherboard: nRFgo Motherboard Setup (nRF6310).

LED assignments:

Buttons assignments:

Testing

The Running Speed and Cadence Application can be tested using the Master Control Panel as follows:

  1. Compile and program the application. Observe that the Advertising LED is lit.
  2. Connect to the device from Master Control Panel (the device will be advertising as 'Nordic_RSC'), then perform service discovery. Observe that the Connected LED is lit, and the Advertising LED is off.
  3. Click the 'Enable services' button on the Master Control Panel. Observe that Running Speed and Cadence notifications are received every second, and Battery Level notifications are received every two seconds.