Developing with ZBOSS SDK for Zigbee
|
Data Structures | |
struct | zb_zdo_callback_info_s |
struct | zb_zdo_default_resp_s |
Macros | |
#define | ZB_ZDO_INVALID_TSN 0xFF |
Typedefs | |
typedef struct zb_zdo_callback_info_s | zb_zdo_callback_info_t |
typedef struct zb_zdo_default_resp_s | zb_zdo_default_resp_t |
Functions | |
void | zb_zdo_get_diag_data (zb_uint16_t short_address, zb_uint8_t *lqi, zb_int8_t *rssi) |
Obtains last known LQI and RSSI values from device with specified short address. More... | |
void zb_zdo_get_diag_data | ( | zb_uint16_t | short_address, |
zb_uint8_t * | lqi, | ||
zb_int8_t * | rssi | ||
) |
Obtains last known LQI and RSSI values from device with specified short address.
short_address | - address of device |
lqi | [in] - pointer to zb_uint8_t variable to store lqi value |
rssi | [in] - pointer to zb_uint8_t variable to store rssi value |
Example: