nxp,kinetis-ftm-pwm

Vendor: NXP Semiconductors

Description

Kinetis FTM PWM

Properties

Properties not inherited from the base binding file.

Name

Type

Details

#pwm-cells

int

Number of items to expect in a pwm specifier

This property is required.

Constant value: 3

prescaler

int

Input clock prescaler

This property is required.

Legal values: 1, 2, 4, 8, 16, 32, 64, 128

Specifier cell names

  • pwm cells: channel, period, flags