Create Augmented Supply PDO Sink value See Table 6-17 Programmable Power Supply APDO - Sink. More...
#include <usbc_pd.h>
Data Fields | |
struct { | |
uint32_t max_current: 7 | |
Maximum Current in 50mA increments. More... | |
uint32_t reserved0: 1 | |
Reserved – Shall be set to zero. More... | |
uint32_t min_voltage: 8 | |
Minimum Voltage in 100mV increments. More... | |
uint32_t reserved1: 1 | |
Reserved – Shall be set to zero. More... | |
uint32_t max_voltage: 8 | |
Maximum Voltage in 100mV increments. More... | |
uint32_t reserved2: 3 | |
Reserved – Shall be set to zero. More... | |
uint32_t reserved3: 2 | |
00b – Programmable Power Supply 01b…11b - Reserved, Shall Not be used Setting as reserved because it defaults to 0 when not set. More... | |
enum pdo_type type: 2 | |
Augmented Power Data Object (APDO). More... | |
}; | |
uint32_t | raw_value |
Raw PDO value. | |
Create Augmented Supply PDO Sink value See Table 6-17 Programmable Power Supply APDO - Sink.
struct { ... } pd_augmented_supply_pdo_sink::@236 |
uint32_t pd_augmented_supply_pdo_sink::max_current |
Maximum Current in 50mA increments.
uint32_t pd_augmented_supply_pdo_sink::max_voltage |
Maximum Voltage in 100mV increments.
uint32_t pd_augmented_supply_pdo_sink::min_voltage |
Minimum Voltage in 100mV increments.
uint32_t pd_augmented_supply_pdo_sink::raw_value |
Raw PDO value.
uint32_t pd_augmented_supply_pdo_sink::reserved0 |
Reserved – Shall be set to zero.
uint32_t pd_augmented_supply_pdo_sink::reserved1 |
Reserved – Shall be set to zero.
uint32_t pd_augmented_supply_pdo_sink::reserved2 |
Reserved – Shall be set to zero.
uint32_t pd_augmented_supply_pdo_sink::reserved3 |
00b – Programmable Power Supply 01b…11b - Reserved, Shall Not be used Setting as reserved because it defaults to 0 when not set.
enum pdo_type pd_augmented_supply_pdo_sink::type |
Augmented Power Data Object (APDO).
SET TO PDO_AUGMENTED