CONFIG_BT_MESH_LIGHT_CTRL_SRV_TIME_FADE_STANDBY_MANUAL

Default fade to Standby time (manual)

Type: int

Help

Default transition time (in milliseconds) for the controlled Lightness Server when entering the Standby state in manual mode. May be reconfigured at runtime by other models in the mesh network.

Direct dependencies

BT_MESH_LIGHT_CTRL_SRV && BT_MESH && BT

(Includes any dependencies from ifs and menus.)

Default

  • 500

Kconfig definition

At <nRF>/subsys/bluetooth/mesh/Kconfig.models:401

Included via <Zephyr>/Kconfig:8<Zephyr>/Kconfig.zephyr:9<BuildDir>/Kconfig/Kconfig.modules:1<nRF>/Kconfig.nrf:25<nRF>/subsys/Kconfig:10<nRF>/subsys/bluetooth/Kconfig:30<nRF>/subsys/bluetooth/mesh/Kconfig:11

Menu path: (Top) → Modules → Nordic nRF Connect → Bluetooth Low Energy → Bluetooth Mesh → nRF BT Mesh Models → Light Lightness Control (LC) Server

config BT_MESH_LIGHT_CTRL_SRV_TIME_FADE_STANDBY_MANUAL
    int "Default fade to Standby time (manual)"
    range 0 16777214
    default 500
    depends on BT_MESH_LIGHT_CTRL_SRV && BT_MESH && BT
    help
      Default transition time (in milliseconds) for the controlled Lightness
      Server when entering the Standby state in manual mode. May be
      reconfigured at runtime by other models in the mesh network.

(The ‘depends on’ condition includes propagated dependencies from ifs and menus.)