◆ sdc_hci_cmd_sp_read_rssi()

uint8_t sdc_hci_cmd_sp_read_rssi ( const sdc_hci_cmd_sp_read_rssi_t p_params,
sdc_hci_cmd_sp_read_rssi_return_t p_return 
)

#include <softdevice_controller/include/sdc_hci_cmd_status_params.h>

Read RSSI.

The description below is extracted from Core_v5.4, Vol 4, Part E, Section 7.5.4

This command reads the Received Signal Strength Indication (RSSI) value from a Controller.

For a BR/EDR Controller, the RSSI parameter returns the difference between the measured Received Signal Strength Indication (RSSI) and the limits of a range selected by the Controller. The lower limit shall correspond to a received power not less than -56 dBm and not greater than 6 dB above the actual sensitivity of the receiver. The upper limit shall be 20±6 dB above the lower limit. A positive RSSI value shall indicate how many dB the RSSI is above the upper limit, a negative value shall indicate how many dB the RSSI is below the lower limit, and zero shall indicate that the RSSI is inside the range.

The returned RSSI value is not required to have any specific accuracy provided that it correctly indicates whether the received signal strength was above the upper limit, below the lower limit, or between the limits.

For an LE transport, the RSSI parameter returns the absolute received signal strength value in dBm to ±6 dB accuracy. If the RSSI cannot be read, the RSSI parameter shall be set to 127.

Event(s) generated (unless masked away): When the HCI_Read_RSSI command has completed, an HCI_Command_- Complete event shall be generated.

Parameters
[in]p_paramsInput parameters.
[out]p_returnExtra return parameters.
Return values
0if success.
Returns
Returns value between 0x01-0xFF in case of error. See Vol 2, Part D, Error for a list of error codes and descriptions.