nrfxlib API 0.1.0
|
uint8_t sdc_hci_cmd_le_set_path_loss_reporting_params | ( | const sdc_hci_cmd_le_set_path_loss_reporting_params_t * | p_params, |
sdc_hci_cmd_le_set_path_loss_reporting_params_return_t * | p_return | ||
) |
#include <softdevice_controller/include/sdc_hci_cmd_le.h>
LE Set Path Loss Reporting Parameters.
The description below is extracted from Core_v5.4, Vol 4, Part E, Section 7.8.119
The HCI_LE_Set_Path_Loss_Reporting_Parameters command is used to set the path loss threshold reporting parameters for the ACL connection identified by the Connection_Handle parameter.
The path loss threshold-based mechanism is described in [Vol 6] Part B, Section 4.5.16. For each zone boundary, the upwards boundary shall equal the threshold plus the hysteresis and the downwards boundary shall equal the threshold minus the hysteresis.
If the Host issues this command with High_Threshold+High_Hysteresis greater than 0xFF or with Low_Threshold less than Low_Hysteresis, the Controller shall return the error code Invalid HCI Command Parameters (0x12).
If the Host issues this command with Low_Threshold greater than High_Threshold or with Low_Threshold+Low_Hysteresis greater than High_Threshold–High_Hysteresis, the Controller shall return the error code Invalid HCI Command Parameters (0x12).
The Min_Time_Spent parameter indicates the minimum time that the Controller shall observe the path loss has crossed the threshold before the Controller generates an event for the threshold crossing. The Host should specify a suitable value based on the connection interval, subrate factor, and Peripheral latency.
If the Host issues this command when path loss monitoring is enabled, the Controller shall override the existing path loss threshold reporting parameters with the parameters provided in this command.
The High_Threshold and the Low_Threshold parameters are common to all PHYs supported by the Controller. However, the Host can reissue this command with suitable parameters whenever a PHY switch is detected.
If the Connection_Handle parameter does not identify a current ACL connection, the Controller shall return the error code Unknown Connection Identifier (0x02).
Event(s) generated (unless masked away): When the HCI_LE_Set_Path_Loss_Reporting_Parameters command has completed, an HCI_Command_Complete event shall be generated.
If the Host issues this command when path loss monitoring is enabled, and if the new parameters mean that the path loss is now in a different zone, an HCI_LE_Path_Loss_Threshold event shall be generated as soon as possible irrespective of the Min_Time_Spent parameter and the timer shall be reset.
If the Host issues this command with High_Threshold parameter set to 0xFF, then the Controller shall not generate an HCI_LE_Path_Loss_Threshold event with Zone_Entered set to 0x02.
[in] | p_params | Input parameters. |
[out] | p_return | Extra return parameters. |
0 | if success. |