ti,lmp90080 (on spi bus)
Vendor: Texas Instruments
Description
These nodes are “lmp90xxx” bus nodes.
Texas Instruments LMP90080 AFE binding
Properties
Top level properties
These property descriptions apply to “ti,lmp90080” nodes themselves. This page also describes child node properties in the following sections.
Properties not inherited from the base binding file.
Name |
Type |
Details |
---|---|---|
|
|
This property is required. Constant value: |
|
|
GPIO specifier that controls power to the device.
This property should be provided when the device has a dedicated
switch that controls power to the device. The supply state is
entirely the responsibility of the device driver.
Contrast with vin-supply.
|
|
|
Reference to the regulator that controls power to the device.
The referenced devicetree node must have a regulator compatible.
This property should be provided when device power is supplied
by a shared regulator. The supply state is dependent on the
request status of all devices fed by the regulator.
Contrast with supply-gpios. If both properties are provided
then the regulator must be requested before the supply GPIOS is
set to an active state, and the supply GPIOS must be set to an
inactive state before releasing the regulator.
|
|
|
Maximum clock frequency of device's SPI interface in Hz
This property is required. |
|
|
Duplex mode, full or half. By default it's always full duplex thus 0
as this is, by far, the most common mode.
Use the macros not the actual enum value, here is the concordance
list (see dt-bindings/spi/spi.h)
0 SPI_FULL_DUPLEX
2048 SPI_HALF_DUPLEX
Legal values: |
|
|
Motorola or TI frame format. By default it's always Motorola's,
thus 0 as this is, by far, the most common format.
Use the macros not the actual enum value, here is the concordance
list (see dt-bindings/spi/spi.h)
0 SPI_FRAME_FORMAT_MOTOROLA
32768 SPI_FRAME_FORMAT_TI
Legal values: |
|
|
SPI clock polarity which indicates the clock idle state.
If it is used, the clock idle state is logic high; otherwise, low.
|
|
|
SPI clock phase that indicates on which edge data is sampled.
If it is used, data is sampled on the second edge; otherwise, on the first edge.
|
|
|
In some cases, it is necessary for the master to manage SPI chip select
under software control, so that multiple spi transactions can be performed
without releasing it. A typical use case is variable length SPI packets
where the first spi transaction reads the length and the second spi transaction
reads length bytes.
|
|
|
Data Ready Bar
|
|
|
RTD current in microampere
|
Deprecated properties not inherited from the base binding file.
(None)
Properties inherited from the base binding file, which defines common properties that may be set on many nodes. Not all of these may apply to the “ti,lmp90080” compatible.
Name |
Type |
Details |
---|---|---|
|
|
Property to identify that a device can be used as wake up source.
When this property is provided a specific flag is set into the
device that tells the system that the device is capable of
wake up the system.
Wake up capable devices are disabled (interruptions will not wake up
the system) by default but they can be enabled at runtime if necessary.
|
|
|
Power domain the device belongs to.
The device will be notified when the power domain it belongs to is either
suspended or resumed.
|
|
|
Automatically configure the device for runtime power management after the
init function runs.
|
|
|
indicates the operational status of a device
Legal values: See Important properties for more information. |
|
|
compatible strings
This property is required. See Important properties for more information. |
|
|
register space
This property is required. See Important properties for more information. |
|
|
name of each register space
|
|
|
interrupts for device
See Important properties for more information. |
|
|
extended interrupt specifier for device
|
|
|
name of each interrupt
|
|
|
phandle to interrupt controller node
|
|
|
Human readable string describing the device (used as device_get_binding() argument)
See Important properties for more information. This property is deprecated. |
|
|
Clock gate information
|
|
|
name of each clock
|
|
|
number of address cells in reg property
Constant value: |
|
|
number of size cells in reg property
|
|
|
DMA channels specifiers
|
|
|
Provided names of DMA channel specifiers
|
|
|
IO channels specifiers
|
|
|
Provided names of IO channel specifiers
|
|
|
mailbox / IPM channels specifiers
|
|
|
Provided names of mailbox / IPM channel specifiers
|
|
|
Do not initialize device automatically on boot. Device should be manually
initialized using device_init().
|
Child node properties
Name |
Type |
Details |
---|---|---|
|
|
Channel identifier.
This property is required. See Important properties for more information. |
|
|
Gain selection:
- ADC_GAIN_1_6: x 1/6
- ADC_GAIN_1_5: x 1/5
- ADC_GAIN_1_4: x 1/4
- ADC_GAIN_1_3: x 1/3
- ADC_GAIN_2_5: x 2/5
- ADC_GAIN_1_2: x 1/2
- ADC_GAIN_2_3: x 2/3
- ADC_GAIN_4_5: x 4/5
- ADC_GAIN_1: x 1
- ADC_GAIN_2: x 2
- ADC_GAIN_3: x 3
- ADC_GAIN_4: x 4
- ADC_GAIN_6: x 6
- ADC_GAIN_8: x 8
- ADC_GAIN_12: x 12
- ADC_GAIN_16: x 16
- ADC_GAIN_24: x 24
- ADC_GAIN_32: x 32
- ADC_GAIN_64: x 64
- ADC_GAIN_128: x 128
This property is required. Legal values: |
|
|
Reference selection:
- ADC_REF_VDD_1: VDD
- ADC_REF_VDD_1_2: VDD/2
- ADC_REF_VDD_1_3: VDD/3
- ADC_REF_VDD_1_4: VDD/4
- ADC_REF_INTERNAL: Internal
- ADC_REF_EXTERNAL0: External, input 0
- ADC_REF_EXTERNAL1: External, input 1
This property is required. Legal values: |
|
|
This property can be used to specify the voltage (in millivolts)
of the reference selected for this channel, so that applications
can get that value if needed for some calculations.
For the internal reference, the voltage can be usually obtained with
a dedicated ADC API call, so there is no need to use this property
in that case, but for other references this property can be useful.
|
|
|
Acquisition time.
Use the ADC_ACQ_TIME macro to compose the value for this property
or pass ADC_ACQ_TIME_DEFAULT to use the default setting for a given
hardware (e.g. when the hardware does not allow to configure the
acquisition time).
This property is required. |
|
|
When set, selects differential input mode for the channel. Otherwise,
single-ended mode is used unless the zephyr,input-negative property is
specified, in which case the differential mode is selected implicitly.
|
|
|
Positive ADC input. Used only for drivers that select
the ADC_CONFIGURABLE_INPUTS Kconfig option.
|
|
|
Negative ADC input. Used only for drivers that select
the ADC_CONFIGURABLE_INPUTS Kconfig option.
When specified, implies the differential input mode for the channel.
|
|
|
ADC resolution to be used for the channel.
|
|
|
Oversampling setting to be used for the channel.
When specified, each sample is averaged from 2^N conversion results
(where N is the provided value).
|
|
|
Output pin selection for the current sources. The actual
interpretation depends on the driver. This is used only for drivers
which select the ADC_CONFIGURABLE_EXCITATION_CURRENT_SOURCE_PIN
Kconfig option.
|
|
|
Output pin selection for the bias voltage. The actual interpretation
depends on the driver. This is used only for drivers which select
the ADC_CONFIGURABLE_VBIAS_PIN Kconfig option.
|
Specifier cell names