zephyr,ipc-openamp-static-vrings
Vendor: Zephyr-specific binding
Description
OpenAMP (RPMsg with static VRINGs) backend
Properties
Properties not inherited from the base binding file.
Name |
Type |
Details |
---|---|---|
|
|
OpenAMP roles
This property is required. Legal values: |
|
|
phandle to the shared memory region
This property is required. |
|
|
WQ priority for the instance. This property is an array composed by the
priority level and the type of priority (PRIO_COOP for cooperative or
PRIO_PREEMPT for preemptive).
For example for a thread priority K_PRIO_COOP(1) in DT we have
priority = <1 PRIO_COOP>;
or for K_PRIO_PREEMPT(2)
priority = <2 PRIO_PREEMPT>;
When this property is missing a default priority of <0 PRIO_PREEMPT> is
assumed.
|
|
|
The size of the buffer used to send data between host and remote. Default
value is RPMSG_BUFFER_SIZE. This property must be the same for host and
remote and preferably a multiple of the cache line size.
|
Deprecated properties not inherited from the base binding file.
(None)
Properties inherited from the base binding file, which defines common properties that may be set on many nodes. Not all of these may apply to the “zephyr,ipc-openamp-static-vrings” compatible.
Name |
Type |
Details |
---|---|---|
|
|
phandle to the MBOX controller (TX and RX are required)
This property is required. |
|
|
MBOX channel names (must be called "tx" and "rx")
This property is required. |
|
|
indicates the operational status of a device
Legal values: See Important properties for more information. |
|
|
compatible strings
This property is required. See Important properties for more information. |
|
|
register space
See Important properties for more information. |
|
|
name of each register space
|
|
|
interrupts for device
See Important properties for more information. |
|
|
extended interrupt specifier for device
|
|
|
name of each interrupt
|
|
|
phandle to interrupt controller node
|
|
|
Human readable string describing the device (used as device_get_binding() argument)
See Important properties for more information. This property is deprecated. |
|
|
Clock gate information
|
|
|
name of each clock
|
|
|
number of address cells in reg property
|
|
|
number of size cells in reg property
|
|
|
DMA channels specifiers
|
|
|
Provided names of DMA channel specifiers
|
|
|
IO channels specifiers
|
|
|
Provided names of IO channel specifiers
|
|
|
Property to identify that a device can be used as wake up source.
When this property is provided a specific flag is set into the
device that tells the system that the device is capable of
wake up the system.
Wake up capable devices are disabled (interruptions will not wake up
the system) by default but they can be enabled at runtime if necessary.
|
|
|
Power domain the device belongs to.
The device will be notified when the power domain it belongs to is either
suspended or resumed.
|
|
|
Automatically configure the device for runtime power management after the
init function runs.
|