Fuel Gauge
The fuel gauge subsystem exposes an API to uniformly access battery fuel gauge devices. Currently, only reading data is supported.
Note: This API is currently experimental and this doc will be significantly changed as new features are added to the API.
Basic Operation
Properties
Fundamentally, a property is a quantity that a fuel gauge device can measure.
Fuel gauges typically support multiple properties, such as temperature readings of the battery-pack or present-time current/voltage.
Properties are fetched using a client allocated array of fuel_gauge_get_property
. This
array is then populated by values as according to its property_type field.
Caching
The Fuel Gauge API explicitly provides no caching for its clients.
API Reference
- group fuel_gauge_interface
Fuel Gauge Interface.
Defines
-
FUEL_GAUGE_AVG_CURRENT
Runtime Dynamic Battery Parameters Provide a 1 minute average of the current on the battery. Does not check for flags or whether those values are bad readings. See driver instance header for details on implementation and how the average is calculated. Units in uA negative=discharging
-
FUEL_GAUGE_CURRENT
Battery current (uA); negative=discharging
-
FUEL_GAUGE_CHARGE_CUTOFF
Whether the battery underlying the fuel-gauge is cut off from charge
-
FUEL_GAUGE_CYCLE_COUNT
Cycle count in 1/100ths (number of charge/discharge cycles)
-
FUEL_GAUGE_CONNECT_STATE
Connect state of battery
-
FUEL_GAUGE_FLAGS
General Error/Runtime Flags
-
FUEL_GAUGE_FULL_CHARGE_CAPACITY
Full Charge Capacity in uAh (might change in some implementations to determine wear)
-
FUEL_GAUGE_PRESENT_STATE
Is the battery physically present
-
FUEL_GAUGE_REMAINING_CAPACITY
Remaining capacity in uAh
-
FUEL_GAUGE_RUNTIME_TO_EMPTY
Remaining battery life time in minutes
-
FUEL_GAUGE_RUNTIME_TO_FULL
Remaining time in minutes until battery reaches full charge
-
FUEL_GAUGE_SBS_MFR_ACCESS
Retrieve word from SBS1.1 ManufactuerAccess
-
FUEL_GAUGE_STATE_OF_CHARGE
Absolute state of charge (percent, 0-100) - expressed as % of design capacity
-
FUEL_GAUGE_TEMPERATURE
Temperature in 0.1 K
-
FUEL_GAUGE_VOLTAGE
Battery voltage (uV)
-
FUEL_GAUGE_SBS_MODE
Battery Mode (flags)
-
FUEL_GAUGE_CHARGE_CURRENT
Battery desired Max Charging Current (mA)
-
FUEL_GAUGE_CHARGE_VOLTAGE
Battery desired Max Charging Voltage (mV)
-
FUEL_GAUGE_STATUS
Alarm, Status and Error codes (flags)
-
FUEL_GAUGE_DESIGN_CAPACITY
Design Capacity (mAh or 10mWh)
-
FUEL_GAUGE_DESIGN_VOLTAGE
Design Voltage (mV)
-
FUEL_GAUGE_SBS_ATRATE
AtRate (mA or 10 mW)
-
FUEL_GAUGE_SBS_ATRATE_TIME_TO_FULL
AtRateTimeToFull (minutes)
-
FUEL_GAUGE_SBS_ATRATE_TIME_TO_EMPTY
AtRateTimeToEmpty (minutes)
-
FUEL_GAUGE_SBS_ATRATE_OK
AtRateOK (boolean)
-
FUEL_GAUGE_COMMON_COUNT
Reserved to demark end of common fuel gauge properties
-
FUEL_GAUGE_CUSTOM_BEGIN
Reserved to demark downstream custom properties - use this value as the actual value may change over future versions of this API
-
FUEL_GAUGE_PROP_MAX
Reserved to demark end of valid enum properties
Typedefs
-
typedef int (*fuel_gauge_get_property_t)(const struct device *dev, struct fuel_gauge_get_property *props, size_t props_len)
Callback API for getting a fuel_gauge property.
See fuel_gauge_get_property() for argument description
-
typedef int (*fuel_gauge_set_property_t)(const struct device *dev, struct fuel_gauge_set_property *props, size_t props_len)
Callback API for setting a fuel_gauge property.
See fuel_gauge_set_property() for argument description
Functions
-
int fuel_gauge_get_prop(const struct device *dev, struct fuel_gauge_get_property *props, size_t props_len)
Fetch a battery fuel-gauge property.
- Parameters:
dev – Pointer to the battery fuel-gauge device
props – pointer to array of fuel_gauge_get_property struct where the property struct field is set by the caller to determine what property is read from the fuel gauge device into the fuel_gauge_get_property struct’s value field.
props_len – number of properties in props array
- Returns:
return=0 if successful, return < 0 if getting all properties failed, return > 0 if some properties failed where return=number of failing properties.
-
int fuel_gauge_set_prop(const struct device *dev, struct fuel_gauge_set_property *props, size_t props_len)
Set a battery fuel-gauge property.
- Parameters:
dev – Pointer to the battery fuel-gauge device
props – pointer to array of fuel_gauge_set_property struct where the property struct field is set by the caller to determine what property is written to the fuel gauge device from the fuel_gauge_get_property struct’s value field.
props_len – number of properties in props array
- Returns:
return=0 if successful, return < 0 if setting all properties failed, return > 0 if some properties failed where return=number of failing properties.
-
struct fuel_gauge_get_property
- #include <fuel_gauge.h>
Public Members
-
uint16_t property_type
Battery fuel gauge property to get
-
int status
Negative error status set by callee e.g. -ENOTSUP for an unsupported property
-
int avg_current
FUEL_GAUGE_AVG_CURRENT
-
bool cutoff
FUEL_GAUGE_CHARGE_CUTOFF
-
int current
FUEL_GAUGE_CURRENT
-
uint32_t cycle_count
FUEL_GAUGE_CYCLE_COUNT
-
uint32_t flags
FUEL_GAUGE_FLAGS
-
uint32_t full_charge_capacity
FUEL_GAUGE_FULL_CHARGE_CAPACITY
-
uint32_t remaining_capacity
FUEL_GAUGE_REMAINING_CAPACITY
-
uint32_t runtime_to_empty
FUEL_GAUGE_RUNTIME_TO_EMPTY
-
uint32_t runtime_to_full
FUEL_GAUGE_RUNTIME_TO_FULL
-
uint16_t sbs_mfr_access_word
FUEL_GAUGE_SBS_MFR_ACCESS
-
uint8_t state_of_charge
FUEL_GAUGE_STATE_OF_CHARGE
-
uint16_t temperature
FUEL_GAUGE_TEMPERATURE
-
int voltage
FUEL_GAUGE_VOLTAGE
-
uint16_t sbs_mode
FUEL_GAUGE_SBS_MODE
-
uint16_t chg_current
FUEL_GAUGE_CHARGE_CURRENT
-
uint16_t chg_voltage
FUEL_GAUGE_CHARGE_VOLTAGE
-
uint16_t fg_status
FUEL_GAUGE_STATUS
-
uint16_t design_cap
FUEL_GAUGE_DESIGN_CAPACITY
-
uint16_t design_volt
FUEL_GAUGE_DESIGN_VOLTAGE
-
int16_t sbs_at_rate
FUEL_GAUGE_SBS_ATRATE
-
uint16_t sbs_at_rate_time_to_full
FUEL_GAUGE_SBS_ATRATE_TIME_TO_FULL
-
uint16_t sbs_at_rate_time_to_empty
FUEL_GAUGE_SBS_ATRATE_TIME_TO_EMPTY
-
bool sbs_at_rate_ok
FUEL_GAUGE_SBS_ATRATE_OK
-
union fuel_gauge_get_property.[anonymous] value
Property field for getting
-
uint16_t property_type
-
struct fuel_gauge_set_property
- #include <fuel_gauge.h>
Public Members
-
uint16_t property_type
Battery fuel gauge property to set
-
int status
Negative error status set by callee e.g. -ENOTSUP for an unsupported property
-
uint16_t sbs_mfr_access_word
FUEL_GAUGE_SBS_MFR_ACCESS
-
uint16_t sbs_mode
FUEL_GAUGE_SBS_MODE
-
int16_t sbs_at_rate
FUEL_GAUGE_SBS_ATRATE
-
union fuel_gauge_set_property.[anonymous] value
Property field for setting
-
uint16_t property_type
-
struct fuel_gauge_driver_api
- #include <fuel_gauge.h>
-
FUEL_GAUGE_AVG_CURRENT