nxp,mcux-12b1msps-sar
Vendor: NXP Semiconductors
Description
NXP MCUA 12B1MSPS SAR ADC
Properties
Top level properties
These property descriptions apply to “nxp,mcux-12b1msps-sar” nodes themselves. This page also describes child node properties in the following sections.
Properties not inherited from the base binding file.
Name |
Type |
Details |
---|---|---|
|
|
clock divider for the converter
This property is required. |
|
|
sample period mode
This property is required. |
|
|
This property is required. Constant value: |
|
|
Pin configuration/s for the first state. Content is specific to the
selected pin controller driver implementation.
|
|
|
Pin configuration/s for the second state. See pinctrl-0.
|
|
|
Pin configuration/s for the third state. See pinctrl-0.
|
|
|
Pin configuration/s for the fourth state. See pinctrl-0.
|
|
|
Pin configuration/s for the fifth state. See pinctrl-0.
|
|
|
Names for the provided states. The number of names needs to match the
number of states.
|
Deprecated properties not inherited from the base binding file.
(None)
Properties inherited from the base binding file, which defines common properties that may be set on many nodes. Not all of these may apply to the “nxp,mcux-12b1msps-sar” compatible.
Name |
Type |
Details |
---|---|---|
|
|
register space
This property is required. See Important properties for more information. |
|
|
interrupts for device
This property is required. See Important properties for more information. |
|
|
number of address cells in reg property
Constant value: |
|
|
number of size cells in reg property
|
|
|
indicates the operational status of a device
Legal values: See Important properties for more information. |
|
|
compatible strings
This property is required. See Important properties for more information. |
|
|
name of each register space
|
|
|
extended interrupt specifier for device
|
|
|
name of each interrupt
|
|
|
phandle to interrupt controller node
|
|
|
Human readable string describing the device (used as device_get_binding() argument)
See Important properties for more information. |
|
|
Clock gate information
|
|
|
name of each clock
|
|
|
DMA channels specifiers
|
|
|
Provided names of DMA channel specifiers
|
|
|
IO channels specifiers
|
|
|
Provided names of IO channel specifiers
|
|
|
mailbox / IPM channels specifiers
|
|
|
Provided names of mailbox / IPM channel specifiers
|
|
|
Property to identify that a device can be used as wake up source.
When this property is provided a specific flag is set into the
device that tells the system that the device is capable of
wake up the system.
Wake up capable devices are disabled (interruptions will not wake up
the system) by default but they can be enabled at runtime if necessary.
|
|
|
Power domain the device belongs to.
The device will be notified when the power domain it belongs to is either
suspended or resumed.
|
Child node properties
Name |
Type |
Details |
---|---|---|
|
|
Channel identifier.
This property is required. See Important properties for more information. |
|
|
Gain selection:
- ADC_GAIN_1_6: x 1/6
- ADC_GAIN_1_5: x 1/5
- ADC_GAIN_1_4: x 1/4
- ADC_GAIN_1_3: x 1/3
- ADC_GAIN_2_5: x 2/5
- ADC_GAIN_1_2: x 1/2
- ADC_GAIN_2_3: x 2/3
- ADC_GAIN_4_5: x 4/5
- ADC_GAIN_1: x 1
- ADC_GAIN_2: x 2
- ADC_GAIN_3: x 3
- ADC_GAIN_4: x 4
- ADC_GAIN_6: x 6
- ADC_GAIN_8: x 8
- ADC_GAIN_12: x 12
- ADC_GAIN_16: x 16
- ADC_GAIN_24: x 24
- ADC_GAIN_32: x 32
- ADC_GAIN_64: x 64
- ADC_GAIN_128: x 128
This property is required. Legal values: |
|
|
Reference selection:
- ADC_REF_VDD_1: VDD
- ADC_REF_VDD_1_2: VDD/2
- ADC_REF_VDD_1_3: VDD/3
- ADC_REF_VDD_1_4: VDD/4
- ADC_REF_INTERNAL: Internal
- ADC_REF_EXTERNAL0: External, input 0
- ADC_REF_EXTERNAL1: External, input 1
This property is required. Legal values: |
|
|
This property can be used to specify the voltage (in millivolts)
of the reference selected for this channel, so that applications
can get that value if needed for some calculations.
For the internal reference, the voltage can be usually obtained with
a dedicated ADC API call, so there is no need to use this property
in that case, but for other references this property can be useful.
|
|
|
Acquisition time.
Use the ADC_ACQ_TIME macro to compose the value for this property
or pass ADC_ACQ_TIME_DEFAULT to use the default setting for a given
hardware (e.g. when the hardware does not allow to configure the
acquisition time).
This property is required. |
|
|
Positive ADC input. Used only for drivers that select
the ADC_CONFIGURABLE_INPUTS Kconfig option.
|
|
|
Negative ADC input. Used only for drivers that select
the ADC_CONFIGURABLE_INPUTS Kconfig option.
When specified, the channel is to be used in differential input mode,
otherwise, single-ended mode is used.
|
|
|
ADC resolution to be used for the channel.
|
|
|
Oversampling setting to be used for the channel.
When specified, each sample is averaged from 2^N conversion results
(where N is the provided value).
|
Specifier cell names
io-channel cells: input