adp536x
The adp536x library provides an API to the ADP5360 power management integrated circuit (PMIC).
Implementation
The library accesses the features of the ADP5360 PMIC by conducting Inter-Integrated Circuit (I2C) transactions with its registers. Generic read, write, and masked write functions are private to the library. The feature-specific functions are available to the user.
Supported features
The library provides several functions to set operating parameters for the ADP5360 PMIC and for reading status values.
Requirements
An I2C interface is required to communicate with the ADP5360 PMIC.
Configuration
To enable the library, set the CONFIG_ADP536X
Kconfig option to y
in the project configuration file prj.conf
.
You can use the I2C bus by setting the CONFIG_ADP536X_BUS_NAME
Kconfig option.
Initialize the library using the adp536x_init()
function and use the API to configure and read from the ADP5360 PMIC.
Dependencies
This library uses the I2C-capable hardware.
API documentation
include/adp536x
lib/adp536x/src
Following define VBUS current limit values, charging current values, and overcharge protection threshold values respectively:
- group adp536x
Defines
-
ADP536X_VBUS_ILIM_50mA
-
ADP536X_VBUS_ILIM_100mA
-
ADP536X_VBUS_ILIM_150mA
-
ADP536X_VBUS_ILIM_200mA
-
ADP536X_VBUS_ILIM_250mA
-
ADP536X_VBUS_ILIM_300mA
-
ADP536X_VBUS_ILIM_400mA
-
ADP536X_VBUS_ILIM_500mA
-
ADP536X_CHG_CURRENT_10mA
-
ADP536X_CHG_CURRENT_50mA
-
ADP536X_CHG_CURRENT_100mA
-
ADP536X_CHG_CURRENT_150mA
-
ADP536X_CHG_CURRENT_200mA
-
ADP536X_CHG_CURRENT_250mA
-
ADP536X_CHG_CURRENT_300mA
-
ADP536X_CHG_CURRENT_320mA
-
ADP536X_OC_CHG_THRESHOLD_25mA
-
ADP536X_OC_CHG_THRESHOLD_50mA
-
ADP536X_OC_CHG_THRESHOLD_100mA
-
ADP536X_OC_CHG_THRESHOLD_150mA
-
ADP536X_OC_CHG_THRESHOLD_200mA
-
ADP536X_OC_CHG_THRESHOLD_250mA
-
ADP536X_OC_CHG_THRESHOLD_300mA
-
ADP536X_OC_CHG_THRESHOLD_400mA
Functions
-
int adp536x_init(const struct device *dev)
Initialize ADP536X.
- Parameters
dev – [in] Pointer to the I2C bus device.
- Return values
0 – If the operation was successful. Otherwise, a (negative) error code is returned.
-
int adp536x_vbus_current_set(uint8_t value)
Set the VBUS current limit.
- Parameters
value – [in] The upper current threshold in LSB.
- Return values
0 – If the operation was successful. Otherwise, a (negative) error code is returned.
-
int adp536x_charger_current_set(uint8_t value)
Set the charger current.
- Parameters
value – [in] The charger current in LSB.
- Return values
0 – If the operation was successful. Otherwise, a (negative) error code is returned.
-
int adp536x_charger_termination_voltage_set(uint8_t value)
Set the charger termination voltage.
This function configures the maximum battery voltage where the charger remains active.
- Parameters
value – [in] The charger termination voltage.
- Return values
0 – If the operation was successful. Otherwise, a (negative) error code is returned.
-
int adp536x_charging_enable(bool enable)
Enable charging.
- Parameters
enable – [in] The requested charger operation state.
- Return values
0 – If the operation was successful. Otherwise, a (negative) error code is returned.
-
int adp536x_charger_status_1_read(uint8_t *buf)
Read the STATUS1 register.
- Parameters
buf – [out] The read value of the STATUS1 register.
- Return values
0 – If the operation was successful. Otherwise, a (negative) error code is returned.
-
int adp536x_charger_status_2_read(uint8_t *buf)
Read the STATUS2 register.
- Parameters
buf – [out] The read value of the STATUS2 register.
- Return values
0 – If the operation was successful. Otherwise, a (negative) error code is returned.
-
int adp536x_oc_chg_hiccup_set(bool enable)
Enable charge hiccup protection mode.
- Parameters
enable – [in] The requested hiccup protection state.
- Return values
0 – If the operation was successful. Otherwise, a (negative) error code is returned.
-
int adp536x_oc_dis_hiccup_set(bool enable)
Enable discharge hiccup protection mode.
- Parameters
enable – [in] The requested hiccup protection state.
- Return values
0 – If the operation was successful. Otherwise, a (negative) error code is returned.
-
int adp536x_buckbst_enable(bool enable)
Enable the buck/boost regulator.
- Parameters
enable – [in] The requested regulator operation state.
- Return values
0 – If the operation was successful. Otherwise, a (negative) error code is returned.
-
int adp536x_buck_1v8_set(void)
Set the buck regulator to 1.8 V.
- Return values
0 – If the operation was successful. Otherwise, a (negative) error code is returned.
-
int adp536x_buckbst_3v3_set(void)
Set the buck/boost regulator to 3.3 V.
- Return values
0 – If the operation was successful. Otherwise, a (negative) error code is returned.
-
int adp536x_factory_reset(void)
Reset the device to its default values.
- Return values
0 – If the operation was successful. Otherwise, a (negative) error code is returned.
-
int adp536x_oc_chg_current_set(uint8_t value)
Set the charge over-current threshold.
- Parameters
value – [in] The over-current threshold.
- Return values
0 – If the operation was successful. Otherwise, a (negative) error code is returned.
-
int adp536x_buck_discharge_set(bool enable)
Set the buck discharge resistor status.
- Parameters
enable – [in] Boolean value to enable or disable the discharge resistor.
- Return values
0 – If the operation was successful. Otherwise, a (negative) error code is returned.
-
ADP536X_VBUS_ILIM_50mA