CONFIG_MAX30101_SLOT2
Slot 2
Type: int
Help
Set which LED and pulse amplitude are active in time slot 2.
0: None (disabled)
1: LED1 (red), LED1_PA
2: LED2 (IR), LED2_PA
3: LED3 (green), LED3_PA
4: None (disabled)
5: LED1 (red), PILOT_PA
6: LED2 (IR), PILOT_PA
7: LED3 (green), PILOT_PA
Direct dependencies
MAX30101_MULTI_LED_MODE
&& MAX30101
&& SENSOR
(Includes any dependencies from ifs and menus.)
Default
0
Kconfig definition
At <Zephyr>/drivers/sensor/max30101/Kconfig:156
Included via <Zephyr>/Kconfig:8
→ <Zephyr>/Kconfig.zephyr:42
→ <Zephyr>/drivers/Kconfig:64
→ <Zephyr>/drivers/sensor/Kconfig:161
Menu path: (Top) → Device Drivers → Sensor Drivers → MAX30101 Pulse Oximeter and Heart Rate Sensor
config MAX30101_SLOT2
int "Slot 2"
range 0 7
default 0
depends on MAX30101_MULTI_LED_MODE && MAX30101 && SENSOR
help
Set which LED and pulse amplitude are active in time slot 2.
0: None (disabled)
1: LED1 (red), LED1_PA
2: LED2 (IR), LED2_PA
3: LED3 (green), LED3_PA
4: None (disabled)
5: LED1 (red), PILOT_PA
6: LED2 (IR), PILOT_PA
7: LED3 (green), PILOT_PA
(The ‘depends on’ condition includes propagated dependencies from ifs and menus.)