CONFIG_MAX30101_LED3_PA

LED2 (green) pulse amplitude

Type: hex

Help

Set the pulse amplitude to control the LED3 (green) current. The
actual measured LED current for each part can vary significantly due
to the trimming methodology.
0x00 = 0.0 mA
0x01 = 0.2 mA
0x02 = 0.4 mA
0x0f = 3.1 mA
0xff = 50.0 mA

Direct dependencies

MAX30101 && SENSOR

(Includes any dependencies from ifs and menus.)

Default

  • 0xff

Kconfig definition

At <Zephyr>/drivers/sensor/max30101/Kconfig:125

Included via <Zephyr>/Kconfig:8<Zephyr>/Kconfig.zephyr:42<Zephyr>/drivers/Kconfig:64<Zephyr>/drivers/sensor/Kconfig:161

Menu path: (Top) → Device Drivers → Sensor Drivers → MAX30101 Pulse Oximeter and Heart Rate Sensor

config MAX30101_LED3_PA
    hex "LED2 (green) pulse amplitude"
    range 0 0xff
    default 0xff
    depends on MAX30101 && SENSOR
    help
      Set the pulse amplitude to control the LED3 (green) current. The
      actual measured LED current for each part can vary significantly due
      to the trimming methodology.
      0x00 = 0.0 mA
      0x01 = 0.2 mA
      0x02 = 0.4 mA
      0x0f = 3.1 mA
      0xff = 50.0 mA

(The ‘depends on’ condition includes propagated dependencies from ifs and menus.)