CONFIG_MAX30101_LED3_PA
LED2 (green) pulse amplitude
Type: hex
Help
Set the pulse amplitude to control the LED3 (green) current. The
actual measured LED current for each part can vary significantly due
to the trimming methodology.
0x00 = 0.0 mA
0x01 = 0.2 mA
0x02 = 0.4 mA
0x0f = 3.1 mA
0xff = 50.0 mA
Direct dependencies
(Includes any dependencies from ifs and menus.)
Default
0xff
Kconfig definition
At <Zephyr>/drivers/sensor/max30101/Kconfig:125
Included via <Zephyr>/Kconfig:8
→ <Zephyr>/Kconfig.zephyr:42
→ <Zephyr>/drivers/Kconfig:64
→ <Zephyr>/drivers/sensor/Kconfig:161
Menu path: (Top) → Device Drivers → Sensor Drivers → MAX30101 Pulse Oximeter and Heart Rate Sensor
config MAX30101_LED3_PA
hex "LED2 (green) pulse amplitude"
range 0 0xff
default 0xff
depends on MAX30101 && SENSOR
help
Set the pulse amplitude to control the LED3 (green) current. The
actual measured LED current for each part can vary significantly due
to the trimming methodology.
0x00 = 0.0 mA
0x01 = 0.2 mA
0x02 = 0.4 mA
0x0f = 3.1 mA
0xff = 50.0 mA
(The ‘depends on’ condition includes propagated dependencies from ifs and menus.)