CONFIG_LM77_TRIGGER
Trigger support
Type: bool
Help
Enable trigger support for the LM77 digital temperature sensor.
Trigger events are based on the LM77 INT signal (configured for event
interrupt mode). After a trigger event the LM77 temperature must be
read in order to reset and rearm the trigger.
Direct dependencies
(Includes any dependencies from ifs and menus.)
Default
y
Kconfig definition
At <Zephyr>/drivers/sensor/lm77/Kconfig:14
Included via <Zephyr>/Kconfig:8
→ <Zephyr>/Kconfig.zephyr:42
→ <Zephyr>/drivers/Kconfig:64
→ <Zephyr>/drivers/sensor/Kconfig:137
Menu path: (Top) → Device Drivers → Sensor Drivers → LM77 Temperature Sensor
config LM77_TRIGGER
bool "Trigger support"
default y
depends on LM77 && SENSOR
help
Enable trigger support for the LM77 digital temperature sensor.
Trigger events are based on the LM77 INT signal (configured for event
interrupt mode). After a trigger event the LM77 temperature must be
read in order to reset and rearm the trigger.
(The ‘depends on’ condition includes propagated dependencies from ifs and menus.)