CONFIG_BT_BUF_EVT_DISCARDABLE_SIZE
Maximum supported discardable HCI Event buffer length
Maximum supported discardable HCI Event buffer length
Type: int
Help
Maximum support discardable HCI event size of buffers in the separate
discardable event buffer pool. This value does not include the
HCI Event header.
The minimum size is set based on the Advertising Report. Setting
the buffer size different than BT_BUF_EVT_RX_SIZE can save memory.
Help
Maximum support discardable HCI event size of buffers in the separate
discardable event buffer pool. This value does not include the
HCI Event header.
The minimum size is set based on the Advertising Report. Setting
the buffer size different than BT_BUF_EVT_RX_SIZE can save memory.
Direct dependencies
BT_RPC_STACK
|| (BT_HCI
&& BT
)
(Includes any dependencies from ifs and menus.)
Defaults
Kconfig definitions
At <Zephyr>/subsys/bluetooth/common/Kconfig:135
Included via <Zephyr>/Kconfig:8
→ <Zephyr>/Kconfig.zephyr:33
→ <Zephyr>/modules/Kconfig:6
→ <nRF>/doc/_build/kconfig/Kconfig.modules:2
→ <nRF>/Kconfig.nrf:92
→ <nRF>/subsys/Kconfig:10
→ <nRF>/subsys/bluetooth/Kconfig:38
→ <nRF>/subsys/bluetooth/rpc/Kconfig:195
Menu path: (Top) → Modules → nrf (/home/runner/work/sdk-nrf/sdk-nrf/ncs/nrf) → Nordic nRF Connect → Bluetooth Low Energy → BLE over nRF RPC
config BT_BUF_EVT_DISCARDABLE_SIZE
int "Maximum supported discardable HCI Event buffer length"
range 43 255
default 255 if BT_BREDR
default 43
depends on BT_RPC_STACK
help
Maximum support discardable HCI event size of buffers in the separate
discardable event buffer pool. This value does not include the
HCI Event header.
The minimum size is set based on the Advertising Report. Setting
the buffer size different than BT_BUF_EVT_RX_SIZE can save memory.
At <Zephyr>/subsys/bluetooth/common/Kconfig:135
Included via <Zephyr>/Kconfig:8
→ <Zephyr>/Kconfig.zephyr:44
→ <Zephyr>/subsys/Kconfig:9
→ <Zephyr>/subsys/bluetooth/Kconfig:179
Menu path: (Top) → Sub Systems and OS Services → Bluetooth
config BT_BUF_EVT_DISCARDABLE_SIZE
int "Maximum supported discardable HCI Event buffer length"
range 43 255
default 255 if BT_BREDR
default 43
depends on BT_HCI && BT
help
Maximum support discardable HCI event size of buffers in the separate
discardable event buffer pool. This value does not include the
HCI Event header.
The minimum size is set based on the Advertising Report. Setting
the buffer size different than BT_BUF_EVT_RX_SIZE can save memory.
(The ‘depends on’ condition includes propagated dependencies from ifs and menus.)