USB HID CDC ACM Application
Overview
This sample app demonstrates use of multiple USB classes with multiple instances. It combines two HID instances and two CDC ACM instances. This sample can be found under samples/subsys/usb/hid-cdc in the Zephyr project tree.
Requirements
This project requires an USB device driver and multiple endpoints.
The board hardware must have a push button connected via a GPIO pin. These are called “User buttons” on many of Zephyr’s Supported Boards.
The button must be configured using the sw0
devicetree
alias, usually in the BOARD.dts file. You will
see this error if you try to build this sample for an unsupported board:
Unsupported board: sw0 devicetree alias is not defined
You may see additional build errors if the sw0
alias exists, but is not
properly defined.
If the devicetree aliases sw1
, sw2
, and sw3
are defined, they will
also be used as additional buttons as described below.
Building and Running
This sample can be built for multiple boards. To build and flash it for the nRF52840 DK board:
west build -b nrf52840dk_nrf52840 samples/subsys/usb/hid-cdc
west flash
After you have built and flashed the sample app image to your board, plug the board into a host device, for example, a PC running Linux. Two CDC ACM interfaces (for example /dev/ttyACM1 and /dev/ttyACM2) and two HID devices will be detected:
usb 2-2: new full-speed USB device number 3 using ohci-pci
usb 2-2: New USB device found, idVendor=2fe3, idProduct=0003, bcdDevice= 2.03
usb 2-2: New USB device strings: Mfr=1, Product=2, SerialNumber=3
usb 2-2: Product: Zephyr HID and CDC ACM sample
usb 2-2: Manufacturer: ZEPHYR
usb 2-2: SerialNumber: 86FE679A598AC47A
cdc_acm 2-2:1.0: ttyACM1: USB ACM device
input: ZEPHYR Zephyr HID and CDC ACM sample as /devices/pci0000:00/0000:00:06.0/usb2/2-2/2-2:1.2/0003:2FE3:0100.0002/input/input8
hid-generic 0003:2FE3:0100.0002: input,hidraw1: USB HID v1.10 Mouse [ZEPHYR Zephyr HID and CDC ACM sample] on usb-0000:00:06.0-2/input2
cdc_acm 2-2:1.3: ttyACM2: USB ACM device
input: ZEPHYR Zephyr HID and CDC ACM sample as /devices/pci0000:00/0000:00:06.0/usb2/2-2/2-2:1.5/0003:2FE3:0100.0003/input/input9
hid-generic 0003:2FE3:0100.0003: input,hidraw2: USB HID v1.10 Keyboard [ZEPHYR Zephyr HID and CDC ACM sample] on usb-0000:00:06.0-2/input5
You can now connect to both CDC ACM ports:
minicom -D /dev/ttyACM1 -b 115200
minicom -D /dev/ttyACM2 -b 115200
After both ports have been connected to, messages explaining usage of each port will be displayed:
Welcome to CDC_ACM_0
Supported commands:
up - moves the mouse up
down - moves the mouse down
right - moves the mouse to right
left - moves the mouse to left
Welcome to CDC_ACM_1
Enter a string and terminate it with ENTER.
It will be sent via HID when BUTTON 2 is pressed.
You can modify it by sending a new one here.
CDC ACM 0 may be used to control the mouse by typing a command and pressing ENTER.
CDC ACM 1 is used to control the keyboard - any string typed into it and finished with ENTER will be saved on the device and typed back to the host when BUTTON 2 is pressed.
Buttons have following functions:
Button 0 moves HID mouse in random direction
Button 1 is a left HID mouse button
Button 2 types the string sent with CDC ACM 1 using HID keyboard
Button 3 is a CAPS LOCK on HID keyboard