nxp,kinetis-adc16

Vendor: NXP Semiconductors

Description

Kinetis ADC16

Properties

Properties not inherited from the base binding file.

Name

Type

Details

channel-mux-b

boolean

Use alternate set (b instead of a) of ADC channels

periodic-trigger

boolean

if periodic trigger enabled

#io-channel-cells

int

This property is required.

Constant value: 1

clk-source

int

use alternate clock reference source

long-sample

int

long sample mode

Legal values: 0, 1, 2, 3, 4

continuous-convert

boolean

If use continuous convert

high-speed

boolean

If use high speed

hw-trigger-src

int

hardware trigger source (See ADCxTRGSEL field in user manual for more details)

Specifier cell names

  • io-channel cells: input