CONFIG_WDT_ITE_WARNING_LEADING_TIME_MS
Number of ms before generating watchdog event/signal
Type: int
Help
This option defines the window in which a watchdog event must be
handled. After this time window, the watchdog reset triggers
immediately.
Default
500
Kconfig definition
At <Zephyr>/drivers/watchdog/Kconfig.it8xxx2:13
Included via <Zephyr>/Kconfig:8
→ <Zephyr>/Kconfig.zephyr:42
→ <Zephyr>/drivers/Kconfig:54
→ <Zephyr>/drivers/watchdog/Kconfig:85
Menu path: (Top) → Device Drivers → Watchdog Support
config WDT_ITE_WARNING_LEADING_TIME_MS
int "Number of ms before generating watchdog event/signal"
default 500
depends on WATCHDOG
help
This option defines the window in which a watchdog event must be
handled. After this time window, the watchdog reset triggers
immediately.
(The ‘depends on’ condition includes propagated dependencies from ifs and menus.)