CONFIG_I2S_STM32_PLLI2S_PLLM
Division factor for PLLI2S VCO input clock
Type: int
Help
Division factor for the audio PLL (PLLI2S) VCO input clock.
PLLM factor should be selected to ensure that the VCO
input frequency ranges from 1 to 2 MHz. It is recommended
to select a frequency of 2 MHz to limit PLL jitter.
Allowed values: 2-63
Direct dependencies
(I2S
&& BOARD_NUCLEO_F411RE
) || (I2S
&& BOARD_NUCLEO_F411RE
) || (I2S
&& BOARD_96B_ARGONKEY
) || (I2S
&& BOARD_96B_STM32_SENSOR_MEZ
) || (I2S
&& BOARD_NUCLEO_F411RE
) || (I2S_STM32_USE_PLLI2S_ENABLE
&& I2S_STM32
&& I2S
)
(Includes any dependencies from ifs and menus.)
Defaults
8
8
8
8
8
8
Kconfig definitions
At <Zephyr>/boards/shields/x_nucleo_iks02a1/boards/nucleo_f411re.defconfig:34
Included via <Zephyr>/Kconfig:8
→ <Zephyr>/Kconfig.zephyr:18
→ <nRF>/doc/_build/kconfig/Kconfig.shield.defconfig:1
→ <Zephyr>/boards/shields/x_nucleo_iks02a1/Kconfig.defconfig:5
Menu path: (Top)
config I2S_STM32_PLLI2S_PLLM
int
default 8
depends on I2S && BOARD_NUCLEO_F411RE
At <Zephyr>/boards/shields/x_nucleo_iks02a1/boards/nucleo_f411re.defconfig:34
Included via <Zephyr>/Kconfig:8
→ <Zephyr>/Kconfig.zephyr:20
→ <Zephyr>/boards/shields/x_nucleo_iks02a1/Kconfig.defconfig:5
Menu path: (Top)
config I2S_STM32_PLLI2S_PLLM
int
default 8
depends on I2S && BOARD_NUCLEO_F411RE
At <Zephyr>/boards/arm/96b_argonkey/Kconfig.defconfig:17
Included via <Zephyr>/Kconfig:8
→ <Zephyr>/Kconfig.zephyr:22
Menu path: (Top)
config I2S_STM32_PLLI2S_PLLM
int
default 8
depends on I2S && BOARD_96B_ARGONKEY
At <Zephyr>/boards/arm/96b_stm32_sensor_mez/Kconfig.defconfig:17
Included via <Zephyr>/Kconfig:8
→ <Zephyr>/Kconfig.zephyr:22
Menu path: (Top)
config I2S_STM32_PLLI2S_PLLM
int
default 8
depends on I2S && BOARD_96B_STM32_SENSOR_MEZ
At <Zephyr>/boards/shields/x_nucleo_iks02a1/boards/nucleo_f411re.defconfig:34
Included via <Zephyr>/Kconfig:8
→ <Zephyr>/Kconfig.zephyr:22
→ <Zephyr>/boards/shields/x_nucleo_iks02a1/Kconfig.defconfig:5
Menu path: (Top)
config I2S_STM32_PLLI2S_PLLM
int
default 8
depends on I2S && BOARD_NUCLEO_F411RE
At <Zephyr>/drivers/i2s/Kconfig.stm32:30
Included via <Zephyr>/Kconfig:8
→ <Zephyr>/Kconfig.zephyr:42
→ <Zephyr>/drivers/Kconfig:44
→ <Zephyr>/drivers/i2s/Kconfig:28
Menu path: (Top) → Device Drivers → I2S bus drivers → STM32 MCU I2S controller driver → Enable usage of PLL
config I2S_STM32_PLLI2S_PLLM
int "Division factor for PLLI2S VCO input clock"
range 2 63
default 8
depends on I2S_STM32_USE_PLLI2S_ENABLE && I2S_STM32 && I2S
help
Division factor for the audio PLL (PLLI2S) VCO input clock.
PLLM factor should be selected to ensure that the VCO
input frequency ranges from 1 to 2 MHz. It is recommended
to select a frequency of 2 MHz to limit PLL jitter.
Allowed values: 2-63